ATMOSPHERE SPARGER
The natural gas or propane is injected into the furnace through a 330 alloy sparger which is located inside the furnace. This sparger helps dissociate the combustible gas before it actually enters the furnace interior. In addition, it helps inject the gas into the furnace under pressure so that it mixes better with the nitrogen for more even process results.
INERT GAS FLOW CONTROL
The inert gas line includes a manual shut off ball valve, pressure regulator, pressure relief valve, pressure gauge, flowmeter with regulating valve, normally open solenoid shut off valve, and check valve.
NATURAL GAS OR PROPANE GAS FLOW CONTROL
The natural gas or propane line includes a manual shut off valve, pressure regulator, pressure gauge, normally closed solenoid for automatic shut off, flowmeter with regulating valve, limiting valve and a special check valve with very low cracking pressure.
LIMITING VALVE FOR NATURAL GAS
A high flow limit valve on the combustible gas line limits the amount of combustible gas that can flow.
ELECTRIC SHUT OFF OF GASES
The natural gas or propane and the inert gas can be shut off from the main electrical control panel with pushbutton control switches.
LOW TEMPERATURE ALARM
The control has a temperature based alarm which is set at 1400F (760C) below which combustible gas cant flow. This is the most important safety system.
INERT GAS LOW FLOW ALARM
The inert gas has a low flow switch to shut off combustibles if inert gas flow is not sufficient to dilute the natural gas or propane to below the Lower Explosive Limit.
DOOR INTERLOCK ALARM
There is a door interlock switch which prevents combustible gas from flowing unless the door is closed.
BURN OFF
A burn off is located at the outlet port of the furnace. This is a pilot burner with automatic shut off system in case of flame out condition. Ignition can be manual or electric.
FLOW CONTROL PANEL
A floor standing flow control panel contains all the flow train components. This panel is constructed of 10 gauge steel from the floor to the top of the panel. The panel has an open back for easy maintenance and 12 deep side panels for protection of the components and neat appearance.
FITTINGS AND PIPING
Pipe is copper. Fittings are brass flare type NPT fittings where possible. These are easy to disassemble for maintenance work and are extremely tight.
ATMOSPHERE INSTRUCTIONS
A very complete instruction manual, specifically written for the atmosphere system, is included. This includes a theory of operation of all major systems and subsystems, full maintenance instructions and schedules, component lists, component instructions and data sheets, emergency procedures, cautions, and start up and shut down procedures. A complete flow schematic of the atmosphere system is provided.
|