877-846-7628
 

GHE SERIES


MOLYBDENUM DISILICIDE ELEMENT BOTTOM LOADING ELEVATOR FURNACES - 3100°F (1700°C)

The GHE SERIES Ultra High Temperature Bottom Loading Elevator Furnaces feature lightweight ultra high temperature ceramic fiber insulation system for fast heat up and low BTU input requirements. The load is placed on an elevator that moves up into the bottom of the fixed furnace. Elements on all four sides provide superior uniformity. The GHE series achieves 3100°F (1700°C) under continuous operation. The insulation system, which is the most fragile and difficult aspect of this type of furnace, is uncompromised in quality and detail. It is guaranteed for one full year, unlike much of the competition where you can expect insulation failure fairly quickly.

FEATURES

MULTILAYERED, EFFICIENT, HIGH ALUMINA CERAMIC FIBER INSULATION
The furnace is insulated with multi-layered high alumina and alumina-silicate ceramic fiber board. The hot face is prefired ceramic fiber board made by Zircar or Rath. Two back up layers of fiber insulation are also used. Triple heat locks are designed into the system for extra protection at high temperatures. A vestibule protects the molybdenum disilicide elements, and prevents excessive heat loss when the bottom is opened. No asbestos is used.

MOLYBDENUM DISILICIDE ELEMENTS
The elements are molybdenum disilicide Super 33 U-shaped elements. These will withstand (3275F) 1800C in air. All electrical connections are at the top, and the elements are suspended from the roof. The electrical resistivity of these elements remains constant over time with little aging. This allows replacement of one element without changing all elements, a distinct advantage over silicon carbide elements. Low watt density is designed into the elements for maximum element life. All aluminum element connection hardware is used to prevent galvanic corrosion. Elements are on all four sides.

DOUBLE WALL CASE CONSTRUCTION
The insulation module has its own rigid refractory board exterior. This insulation module is inserted into a ventilated steel casing leaving an air space between the exterior case and the insulation module. This allows for cooling of the insulation, important in long insulation life, and helps maintain a cool external case temperature. The case is primed with 800F silicone paint and finished in machine enamel.

DEEP PLUG BOTTOM CONSTRUCTION
The bottom features a deep plug type seal with triple heat locks. A vestibule around the bottom opening reduces heat loss and helps protect the elements.

ELECTRIC ELEVATOR
The bottom rises and lowers into the furnace by means of an electric gear motor.

TEMPERATURE UNIFORMITY OF +/-10C ( +/-18F)
Uniformity of +/- 10C (+/-18F) is normal above 1200C (2200F) within 2/3 of the working dimensions. The fact that the elements are on all four sides makes the uniformity particularly good.

ALUMINA HEARTH SUPPORTED FROM COLD FACE
The hearth is a series of flat alumina plates supported by a series of insulating alumina posts which transfer the weight of the hearth all the way to the bottom of the cold face of the bottom insulation.

FAST HEAT UP AND COOL DOWN
The all fiber insulation and Kanthal Super 33 elements provide fast heating and cooling response.

PID DIGITAL CONTROL , HIGH LIMIT CONTROL AND SCR POWER CONTROL
The standard control used is a Honeywell UDC 2300 digital PID 3 mode tuning control. All fuses, transformers, contactors, and controls are located in a NEMA 1 panel. A matched transformer and phase angle fired SCR controls power to the elements. This insures even, precise control and long element life. The thermocouples are Type B. The control voltage is 120 volts. A NEMA 13 lighted On/Off switch and NEMA 13 door power cut off switch are included. A Honeywell UDC 2300 digital high limit back up control with manual reset, back up contactors and separate thermocouple is standard. Customer must connect fused power supply to single point on panel.

TESTING AND INSTRUCTIONS
The furnace is tested to insure circuit integrity. A complete instruction manual includes easy start up instructions, theory of operation, maintenance instructions, parts list, and a detailed trouble shooting guide. A ladder logic diagram and panel layout are prepared on system for easy readability.

WARRANTY
The furnace and insulation module are warranted for one year except for elements and thermocouples (warranted for 6 months.)


OPTIONS


  • JIC CONTROL OPTION: This includes a NEMA 12 control cabinet, all oil tight switches and a panel mounted fused disconnect switch.
  • CONTROL, RECORDER AND ELECTRICAL OPTIONS
  • DIFFERENT TEMPERATURE RATINGS: The same design is available in reduced temperature ratings at a lower cost. There are various grades of elements and insulation that can be used.

SPECIFICATIONS

MODEL NUMBER
WORKING DIMENSIONS
INSIDE CHAMBER DIMENSIONS
OUTSIDE DIMENSIONS
ELEMENT NO & SIZE
K.W.
MAX LOAD WEIGHT
SHIP WEIGHT
 
W
H
D
IW
IH
ID
OW
OH
OD
 
 
 
 
GHE 12
12
12
12
16
14
16
33
90
39
8 - 6/12
8
60
1500
GHE 15
15
15
15
19
17
19
36
96
42
12 - 6/12
16
100
2000
GHE 24
24
24
24
28
26
28
45
114
51
16 - 6/12
40
200
3000
GHE 36
36
36
36
40
38
40
57
138
63
24 - 6/12
80
500
5000
Weight is in pounds. All dimensions are in inches except size of elements which are in millimeters (i.e. 6/12 means 6 mm for main body of element and 12 mm for terminal end). Outside dimensions shown do not include control panels. Hearth height is 42” from floor. Control panel is 17” wide by 60” high by 36” long. 240 or 460 volts is normal. 208, 380 and 575 volts are optional. Larger sizes are available by special quote. Heavier hearth loading is optional. Load weight must be evenly distributed. Specifications subject to change without notice.